printing & paper
providing world-class facilities and solutions to soar greater heights

Printing industry is consistently outpacing the national GDP growth. This growth was fuelled by literacy growth, innovative printing machinery, inexpensive resources, imports, FDI and so on. At 12% per annum, today the printing industry is worth over $600-Billion.

It comes with allied industries like Printing Machinery Manufacturers, Packaging, Paper, Ink and Raw Material Manufacturers and Consumables. But, most companies in the trade are located away from each other. This often results into communication gap, damage of raw material in transportation, higher production cost and related issues.

We, at Renaissance are well aware of these issues. Hence, we have introduced a Printing Industry Cluster to bring this industry and its allied industries together. We are providing world-class facilities and solutions, so that this booming industry gets a new launch pad to soar greater heights.

THE INDUSTRIAL ESTATE SPECIFICATIONS FOR GALA

Download Floor Plan

WORLD-CLASS GLOBAL STANDARD PEB WAREHOUSES
40,000 SQ. FT. ONWARDS

Plans & Drawing

WAREHOUSE SPECIFICATION

  • Foundation
  • Below ground level on surface having bearing capacity 20 ton/ sq. mt. RCC work as per IS 456:2000, IS 2950.
  • Column
  • RCC column up to plinth level.
  • Plinth Height
  • Uniform height of 1.2m (4'-0") from FGL with 0 slopes.
  • Flooring FM2 Floor
  • M25 Grade, 150mm thick, Steel fibre reinforced concrete (SFRC), dry shake hardener with Liquid Surface Hardener (LSH) - Flatness - Evaluating provision of FM2 Floor Panels of 5.45 m x 5.45 m with UDL capacity of 7 tons per sq. m. designed for installation of Selective Racking Systems and Material Handling Equipment like Stackers, Reach Trucks and HPTs. Floor with Truss Screeding.
  • Walls
  • Concrete block wall 200 mm thick to facilitate insulation to improve indoor air quality. 3.90 m high above plinth with 23 mm external sand faced plaster and 12 mm internal cement plaster and internal wall partitions.
  • Lintel/ Beam
  • As per RCC design.
  • Internal Paint
  • OBD
  • External
  • Paint Cement paint.
  • Openings
  • Hand Gear Operated, GI Rolling Shutters - 3.0m width x 3.2m height.
  • Loading Platform
  • Continuous platform providing 2.175m of clear space for external marshalling. Angular docking at 20 degrees, Width of platform 2175 mm + Angular bay, For L/U, aggregating to 2820mm width & straight docking for 2 corner unit.
  • Dock Fenders
  • Dock fenders of high density rubber fitted on anchor bolts for protection of platform edge.
  • Emergency Exit
  • Provision of additional emergency exit doors at rear walls.
  • Security Gates and Cabins
  • Provision of security gate with security cabin at entry & exit (Total 2 Nos. for all 16 units)
  • P.E.B.
  • Pre Engineered Building
  • Size
  • -
  • Clear Height
  • 8m
  • Mid Height
  • 10m
  • Wall Sheet Cladding
  • 0.50mm (TCT) Colour Coated above 3.9m Block wall
  • Roof Sheeting
  • Minimum 0.55 mm TCT Bare Galvalume with Standing Seam, "Double Lock 360 degree Crimped Roofing System with No End Laps, Metal End Closures at Eve, FM Global Approved, based on NCI Building System INC Design. Continuous length from ridge to eaves gutter.
  • Roof Type
  • FM Compliant - Screw less - Standing Seam (SS 2000)
  • Rainwater Gutters
  • Colour Coated Galvalume Gutters with down take pipes fixed with end spouts up to Finished Ground Level.
  • Natural Light
  • Through sidewall cladding 3% (2mm thick Polycarbonate Sheets)
  • Ridge Ventilators
  • 0.9 m wide Throat Continuous Ridge Ventilators.
  • Canopy
  • Continuous Canopy of 4.0m overhangs with soffit.
  • Canopy Soffit Sheet
  • Single Skin 0.50mm TCT, pre-painted, with min yield strength of 550n/mm2, confirming to ASTM A-325.
  • Canopy Wall Cladding
  • Single Skin 0.50mm TCT, pre-painted, with min yield strength of 550n/mm2, confirming to ASTM A-325.
  • Canopy Gutters and Down Pipes
  • Gutter system with down pipes embedded within soffit. 100 mm Galvalume profile down spouts to be provided up to the road level, fixed on required saddle, line & level.
  • Safety Ladder
  • 2 Cage Ladders, one on each side of Gable ends are provided to access roof from existing FRL.
  • Lightening Arrestor Fixing Arrangement
  • Provision of fixing the lighting arrestor.
  • Collateral Load
  • Not Considered.
  • Building Insulation
  • Aluminium reflective insulation - Polynum Super Fire Retardant, providing an average of 6 to 7 degrees centigrade difference between ambient and internal.
  • Plumbing/ Sewerage System
  • Up to tapping point only.
  • Water
  • Provision for water supply.
  • Electrical
  • All installations in accordance with Industrial Norms for Warehouse with IS specification. Provided for Stacker Charging Stations and other gadgets at each Bay. Metal Halide High Bay Lamps, Focus Lights at Loading Bays, Canopy Lighting.
  • Lighting
  • Warehouse Internal Lighting - 150 lux, Canopy 100 lux, External 30 lux.
  • Fire Fighting
  • Fire Hydrant with Hose Reels, Fire Egress Exit Doors, Emergency Exit Signs.
  • Exclusive Road
  • 17 m (56'-0") exclusive road with loading/ unloading platform with gate & security cabin at entry & exit.
  • Landscaped Area
  • Landscaped area at entry & exit points to enhance aesthetics of the Warehouse.
  • Signage
  • Objective to Identify Structures, Areas, Guide People, Vehicle and Material, Caution and Instructions.
  • Power Supply
  • 10 KVA for each unit

Download Brochure in PDF Format